AQ6374 Overview and Applications
The Yokogawa AQ6374 measures spectra across visible and near-infrared wavelengths. It is suited to laser and broadband-source characterization and wavelength-dependent fiber-loss measurements. Eight resolution settings let engineers balance spectral detail and measurement needs.
Measurement and Analysis
Seven traces can be displayed together for comparison. Built-in analysis covers laser, LED, optical-filter, and color measurements. A purge connection helps reduce water-vapor absorption within the monochromator. The internal reference source supports optical alignment and wavelength calibration.
Applications and Automation
- Characterize visible-to-telecom laser sources and broadband emitters.
- Measure optical-fiber loss versus wavelength with a suitable external source.
- Evaluate visible LED spectra and color.
- Integrate remote measurements using GP-IB, RS-232, or Ethernet; Ethernet supports TCP/IP and VXI-11 or socket control.
Model and Configuration Notes
Yokogawa lists the AQ6374 as discontinued in November 2023 and identifies the AQ6374E as its successor. This listing describes the AQ6374. Confirm the unit’s connector adapters, supplied accessories, condition, and calibration records with your quotation.
Specification conditions: [A] 0.05 nm resolution. [A–C] 9.5/125 µm SM fiber after internal alignment, without purge gas. [B] Absolute level display, resolution ≥0.2 nm. [C] Specified PC-polished SM fiber. Sensitivity and sweep figures assume pulse mode off. [D] 1,001 points, one average; excludes 570–580 and 900–1000 nm. Performance temperature: 18–28°C. Follow the English guide for complete conditions, warm-up, and calibration.
AQ6374 Technical Specifications
Optical Performance
- Wavelength range
- 350–1750 nm
- Resolution settings
- 0.05, 0.1, 0.2, 0.5, 1, 2, 5, and 10 nm
- Wavelength accuracy
- ±0.2 nm overall; ±0.05 nm at 1523 nm and at 633 nm after 633 nm HeNe calibration [A]
- Wavelength repeatability
- ±0.015 nm over 1 minute [A]
- Minimum wavelength sampling interval
- 0.002 nm
- Sampling points
- 101–100,001; AUTO available
- Level sensitivity
- −70 dBm at 400–900 nm; −80 dBm at 900–1600 nm; HIGH3 [B]
- Maximum safe total input
- +10 dBm at 400–550 nm; +20 dBm at 550–1750 nm [B]
- Level accuracy
- ±1.0 dB at 1550 nm, −20 dBm input, HIGH1–HIGH3 [B,C]
- Level linearity
- ±0.2 dB for −40 to 0 dBm input, HIGH1–HIGH3 [B]
- Close-in dynamic range
- 60 dB at peak ±1 nm (633/1523 nm); 0.05 nm resolution [A]
- Sweep time
- 0.5 s at NORM_AUTO, span ≤100 nm [D]
Fiber Input and Bench Integration
- Supported fibers
- SM 9.5/125 µm; GI 50/125 and 62.5/125 µm; large-core fibers up to 800 µm
- Remote interfaces
- GP-IB, RS-232, Ethernet (TCP/IP); socket and VXI-11 Ethernet modes
- Bench size and mass
- Approx. 426 × 221 × 459 mm (W × H × D), excluding protectors/handle; approx. 19 kg
销售与服务
- 保修
- 6个月保修
- 校准状态
- 可提供校准证书或测试报告(如报价单中所述)
- 制造商列出的标准配件
- Original manufacturer list: one regional power cord (none with -Y); two A9088ZM rubber feet supplied as one sheet; one A1023US manual CD; one each of the Getting Started Guide, China document, safety manual and worldwide contact list. Manufacturer-listed standard accessories are a reference to the original model documentation. They do not guarantee the contents of a used instrument shipment. Confirm the actual supplied items for the specific unit before ordering.
文件
为什么选择与我们合作?
我们会与您核对相关细节
从规格到配件,我们帮助您了解产品包含哪些内容。.
清楚自己买的是什么
我们会分享我们对该病情的了解,以及所有可提供的记录。.
请告诉我们您的需求
有具体的要求或截止日期吗?我们将专注于您关心的重点。.
没必要从头开始
我们会记录您的提问和之前的讨论内容,因此您可以轻松地从上次讨论的地方继续。.
A closer look at AQ6374

咨询此产品
请告知您的需求,我们将根据当前的产品背景进行评估。.
谢谢
您的咨询已记录在案。请保留此处显示的确认编号。.